SMIT Commands
Commands
The adapter management commands available in SMIT are in
the devices menu under Cambex Fibre Channel Adapter:
List all Cambex FC adapters
This provides the name and location of each adapter.
Change / Show Characteristics of a Cambex FC Adapter
Allows the user to display and modify attributes. Attributes
(and default values) include:
exec_throttle (256) number of simultaneous I/O operations.
dma_window (64) PCI DMA memory window in MB.
retry_delay (3) Delay in seconds after bus reset or other error.
logout_delay (7) Time in seconds allowed for ports to be logged
out before failing I/O.
topology_list (LOOP_P2P) Automatically detect topology.
May also be forced to LOOP_ONLY or P2P_ONLY.
frame_size (2048) Maximum FC frame size. Choices are 1024
or 2048.
infinity (300) Maximum SCSI command timeout in seconds.
Set to 0 to disable.
GHz (auto) Auto-detect fibre channel rate in GHz. May also be
forced to 1 or 2. Ignored on 1GHz cards.